Rose debug info
---------------

Smartctl установка в esxi 5.5 u2 6.0 и прочие

Для полуяения полного отчета ставим пакет

  1. Download
  2. Copy the VIB to the /tmp/ directory of an ESXi host
  3. SSH to the ESXi host
  4. Set the VIB acceptance level to CommunitySupported
  5. # esxcli software acceptance set —level=CommunitySupported
  6. Install the package (Maintenance Mode or Reboot is not required)
  7. #esxcli software vib install -v /tmp/smartctl-6.6-4321.x86_64.vib

The tool is located at /opt/smartmontools/smartctl and works just like the Linux version.
Locate physical disks with ls -l /dev/disks/

/opt/smartmontools/smartctl -d [Device Type] —all /dev/disks/[DISK]

# smartctl -d sat —all /dev/disks/t10.ATA_____Samsung_SSD_850_EVO_M.2_250GB___________S24BNXAG805065D_____
smartctl 6.6 2016-05-10 r4321 [x86_64-linux-6.0.0] (daily-20160510)
Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Family:     Samsung based SSDs
Device Model:     Samsung SSD 850 EVO M.2 250GB
Serial Number:    S24BNXAG805065D
LU WWN Device Id: 5 002538 d404b9f9f
Firmware Version: EMT21B6Q
User Capacity:    250,059,350,016 bytes [250 GB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    Solid State Device
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ACS-2, ATA8-ACS T13/1699-D revision 4c
SATA Version is:  SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
SMART support is: Available — device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART Status not supported: Incomplete response, ATA output registers missing
SMART overall-health self-assessment test result: PASSED
Warning: This result is based on an Attribute check.

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever
                                        been run.
Total time to complete Offline
data collection:                (    0) seconds.
Offline data collection
capabilities:                    (0x53) SMART execute Offline immediate.
                                        Auto Offline data collection on/off support.
                                        Suspend Offline collection upon new
                                        command.
                                        No Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        ( 133) minutes.
SCT capabilities:              (0x003d) SCT Status supported.
                                        SCT Error Recovery Control supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  5 Reallocated_Sector_Ct   0x0033   100   100   010    Pre-fail  Always       —       0
  9 Power_On_Hours          0x0032   099   099   000    Old_age   Always       —       5040
 12 Power_Cycle_Count       0x0032   099   099   000    Old_age   Always       —       35
177 Wear_Leveling_Count     0x0013   094   094   000    Pre-fail  Always       —       122
179 Used_Rsvd_Blk_Cnt_Tot   0x0013   100   100   010    Pre-fail  Always       —       0
181 Program_Fail_Cnt_Total  0x0032   100   100   010    Old_age   Always       —       0
182 Erase_Fail_Count_Total  0x0032   100   100   010    Old_age   Always       —       0
183 Runtime_Bad_Block       0x0013   100   100   010    Pre-fail  Always       —       0
187 Uncorrectable_Error_Cnt 0x0032   100   100   000    Old_age   Always       —       0
190 Airflow_Temperature_Cel 0x0032   049   034   000    Old_age   Always       —       51
195 ECC_Error_Rate          0x001a   200   200   000    Old_age   Always       —       0
199 CRC_Error_Count         0x003e   100   100   000    Old_age   Always       —       0
235 POR_Recovery_Count      0x0012   099   099   000    Old_age   Always       —       26
241 Total_LBAs_Written      0x0032   099   099   000    Old_age   Always       —       6345601655

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]

Warning! SMART Selective Self-Test Log Structure error: invalid SMART checksum.
SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
  255        0    65535  Read_scanning was never started
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
Поделиться
Отправить
 398   2021   esxi