Smartctl установка в esxi 5.5 u2 6.0 и прочие
Для полуяения полного отчета ставим пакет
- Download
- Copy the VIB to the /tmp/ directory of an ESXi host
- SSH to the ESXi host
- Set the VIB acceptance level to CommunitySupported
- # esxcli software acceptance set —level=CommunitySupported
- Install the package (Maintenance Mode or Reboot is not required)
- #esxcli software vib install -v /tmp/smartctl-6.6-4321.x86_64.vib
The tool is located at /opt/smartmontools/smartctl and works just like the Linux version.
Locate physical disks with ls -l /dev/disks/
/opt/smartmontools/smartctl -d [Device Type] —all /dev/disks/[DISK]
# smartctl -d sat —all /dev/disks/t10.ATA_____Samsung_SSD_850_EVO_M.2_250GB___________S24BNXAG805065D_____
smartctl 6.6 2016-05-10 r4321 [x86_64-linux-6.0.0] (daily-20160510)
Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Samsung based SSDs
Device Model: Samsung SSD 850 EVO M.2 250GB
Serial Number: S24BNXAG805065D
LU WWN Device Id: 5 002538 d404b9f9f
Firmware Version: EMT21B6Q
User Capacity: 250,059,350,016 bytes [250 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
SMART support is: Available — device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART Status not supported: Incomplete response, ATA output registers missing
SMART overall-health self-assessment test result: PASSED
Warning: This result is based on an Attribute check.
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
capabilities: (0x53) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 133) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always — 0
9 Power_On_Hours 0x0032 099 099 000 Old_age Always — 5040
12 Power_Cycle_Count 0x0032 099 099 000 Old_age Always — 35
177 Wear_Leveling_Count 0x0013 094 094 000 Pre-fail Always — 122
179 Used_Rsvd_Blk_Cnt_Tot 0x0013 100 100 010 Pre-fail Always — 0
181 Program_Fail_Cnt_Total 0x0032 100 100 010 Old_age Always — 0
182 Erase_Fail_Count_Total 0x0032 100 100 010 Old_age Always — 0
183 Runtime_Bad_Block 0x0013 100 100 010 Pre-fail Always — 0
187 Uncorrectable_Error_Cnt 0x0032 100 100 000 Old_age Always — 0
190 Airflow_Temperature_Cel 0x0032 049 034 000 Old_age Always — 51
195 ECC_Error_Rate 0x001a 200 200 000 Old_age Always — 0
199 CRC_Error_Count 0x003e 100 100 000 Old_age Always — 0
235 POR_Recovery_Count 0x0012 099 099 000 Old_age Always — 26
241 Total_LBAs_Written 0x0032 099 099 000 Old_age Always — 6345601655
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]
Warning! SMART Selective Self-Test Log Structure error: invalid SMART checksum.
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
255 0 65535 Read_scanning was never started
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.